PIRA 5L20.20 - RLC Circuits AC: RLC - Resonance
Instructions / Notes:
- Move the large knife switch in center of the circuit board to the AC
position.
- Check to see the capacitor is not shorted. (See illustration below)
- Capacitor and Inductor are connected in series.
- Flip on the main power switch.
- Move the iron core in and out of the ~3 henry inductor coil.
- The light bulb's brightness indicates the resonance point.
- Demo Uses 120 V. A.C. Be cautious at what you touch. Disconnect
After Each Use.
Photo Shows the Apparatus used by the University of Texas at Austin.
Last Updated 3/98 - University of Texas at Austin Physics Dept. -